Among the most efficient systems on the market based on distributed energy, the Heat Commander is a central heating system that is both cutting edge and accessible thanks to its innovative design and ease of use. EPA certified, its 310,000 BTU capacity makes this furnace versatile and ideal for heating spaces up to 2,500 ft². The Heat Commander’s overall thermal power is notably much higher than most comparable systems.
Included: blower, thermostat, hot air plenum, combustion-state indicator light, automated combustion control, ash lip, ash drawer, poker and scraper
FEATURES:
Heating area
1,000 - 2,500Ft2
Maximum Burn Time
10 h
Maximum log length
21"
Intuitive start mode for fast and clean ignition
Optimized combustion for low creosote formation
Uninterrupted heat with on-demand boost based on thermostatic demand
Among the lowest burn rates on the market (firewood savings)
Up to 10 hours burn time
3.6 ft³ firebox
21'' logs (loading over depth and width)
EPA certified
Proudly made in Canada
Limited lifetime warrant
Air filters help filter dirt before distributing hot air in your installation in addition to protecting the blower. The use of filters is strongly recommended.
The fresh air return adapter can be added to the blower box to increase the efficiency of your system. This option allows you to take fresh air from the rooms and bring it to the furnace to be heated and redistributed in these same rooms. It allows more even air circulation to increase comfort.
SPECIFICATIONS:
General Features:
High-efficiency certified appliance
Yes, EPA 2020 approved
Maximum log length
21"
Log positioning
Loading over width and over depth
Chimney diameter
6"
Flue outlet diameter
6"
Type of chimney
CAN/ULC S629, UL 103 HT (2100 °F)
Baffle type
C-Cast or equivalent
Approved for a mobile home installation
No
Shipping Weight
740 lb (337 kg)
Door type
Single, glass with cast iron frame
Glass type
Ceramic glass
Glass surface – dimensions (Width X Height)
12 3/8 X 10 1/8"
Glass air-wash system
Yes
Blower (hp / speed / CFM)
1/3 | 1 | 1,135
Filter – dimensions (Width X Height X Depth)
15" X 20" X 1"
Overall dimension (Height)
63 1/2"
Overall dimension (Width)
27 3/4"
Overall dimension (Depth)
51 1/8"
Door opening – dimension (Height)
10"
Door opening - dimension (Width)
13 3/4"
Firebox – dimension (Height)
16 3/8"
Firebox – dimension (Width)
18 1/2"
Firebox – dimension (Depth)
22 3/4"
Firebox lined with refractory bricks for better heat distribution
Yes
Stainless-steel secondary-air system improving gas combustion
Yes
Steel thickness – body
3/16"
Steel thickness – top
1/4"
Hot air plenum – dimension (Depth or Height)
22 3/8" - 47 7/8"
Hot air plenum – dimension (Width)
26 7/8"
USA standard (emissions)
EPA
Canadian Standard (emissions)
CSA B415.1-10
USA standard (safety)
UL 391
Canadian standard (safety)
CAN/CSA B366.1
Tested and listed as per applicable standards
By an accredited laboratory (CAN/USA)
Warranty
Limited lifetime
Appliance Performance:
Fuel type
Dry cordwood (16" recommended)
Recommended heating area(12)
1,000 - 2,500 ft²
Overall firebox volume
3.6 ft³
Maximum burn time(12)
10 h
Maximum input capacity (dry cordwood)(1)
310,000 BTU
Nominal heat output at 15lb/ft³ fuel loading density
75,000 BTU
Minimum overall heat output rate(7)
19,354 BTU/h (5.6 kW)
Maximum overall heat output rate(7)
47,052 BTU/h (13.8 kW)
Minimum average overall efficiency (HHV)(11)(10)
76.6 %
Maximum average overall efficiency (LHV)(11)(9)
82 %
Minimum delivered heat output rate(6)
13,297 BTU/h (3.9 kW)
Maximum delivered heat output rate(6)
42,234 BTU/h (12.4 kW)
Minimum average delivered efficiency (HHV)(8)(10)
60.7 %
Maximum average delivered efficiency (LHV)(8)(9)
65 %
Optimum efficiency(3)
83.2%
Optimum heat transfer efficiency
81 %
Average particulate emission rate(4)(5)
0.095 lb/mmBTU (0.041 g/MJ)
Average CO(13)
8.78 lb/mmBTU (3.78 g/MJ)
Average electrical power consumption(2)
330 W
Size
Extra Large
High-efficiency certified appliance
Yes, EPA 2020 approved
Certified according to applicable standards
By an accredited laboratory (CAN/USA)
Premium quality blower included (CFM)
Included
Blower (hp | speed | CFM)
1/3 | 1 | 1,135
Stainless-steel secondary-air system
Yes
Flue outlet diameter
6"
Recommended chimney diameter
6"
Type of chimney
CAN/ULC S629, UL 103 HT (2100 °F)
Overall dimension (Width)
27 3/4"
(1)Based on delivered heat output.
(2)This appliance is officially tested and certified by an independent agency.
(3)Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%.
()Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum.
(4)Input value at 10 lb/ft³ fuel loading density and dry energy value of 8,600 BTU/lb.
(5)Overall : Radiated and delivered heat together at 10 lb/ft³ fuel loading density over one total burn cycle.
(6)Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(7)Higher Heating Value of the fuel.
(8)Lower Heating Value of the fuel.
(9)Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.
(10)Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. LHV % is based on manufacturer’s estimation.
(11)Optimum overall efficiency at a specific burn rate (LHV).
(12)The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
(13)Carbon Monoxyde. Based on overall heat output at 10 lb/ft³ fuel loading density.
(14)Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
Clearances:
United-States
Single wall pipe
Double wall pipe
Clearance – back wall
14 1/4"
6 3/4"
Clearance – ducts
1" (plenum=5")
Clearance – top (measured from the platform on which the appliance is installed)**
69"
Clearance – recommended for maintenance on option side
Freight Shipments ship via Freight Curbside delivery. In other words, the shipping carrier will drop off your item on your property not inside your home. The shipping courier will call ahead of time and schedule a drop off date with you. In some cases, white glove delivery is available. Call Us for additional details.
We have a THOR oven that we now need to return .. physically ourselves.. unhook the gas load in a truck we need to rent ...pay a restocking fee.... After 4 months and more then 6 SEARS repair appointments . SEARS cancelled.. last minute 3 times ..lost work.. horrible experience with THOR.